64bit Integer Output Record (int64out)

This record type is normally used to send an integer value of up to 64 bits to an output device. The record supports alarm, drive, graphics and control limits.

Parameter Fields

The record-specific fields are described below.

Output Value Determination

These fields control how the record determines the value to be output when it gets processed:

Field

Summary

Type

DCT

Default

Read

Write

CA PP

OMSL

Output Mode Select

MENU menuOmsl

Yes

Yes

Yes

No

DOL

Desired Output Link

INLINK

Yes

Yes

Yes

No

DRVH

Drive High Limit

INT64

Yes

Yes

Yes

Yes

DRVL

Drive Low Limit

INT64

Yes

Yes

Yes

Yes

VAL

Desired Output

INT64

Yes

Yes

Yes

Yes

The following steps are performed in order during record processing.

Fetch Value

The OMSL menu field is used to determine whether the DOL link field should be used during processing or not:

  • If OMSL is supervisory the DOL link field is not used. The new output value is taken from the VAL field, which may have been set from elsewhere.

  • If OMSL is closed_loop the DOL link field is used to obtain a value.

Drive Limits

The output value is clipped to the range DRVL to DRVH inclusive, provided that DRVH > DRVL. The result is copied into the VAL field.

Output Specification

These fields control where the record will read data from when it is processed:

Field

Summary

Type

DCT

Default

Read

Write

CA PP

DTYP

Device Type

DEVICE

Yes

Yes

Yes

No

OUT

Output Specification

OUTLINK

Yes

Yes

Yes

No

The DTYP field selects which device support layer should be responsible for writing output data. The int64out device support layers provided by EPICS Base are documented in the “Device Support” section. External support modules may provide additional device support for this record type. If not set explicitly, the DTYP value defaults to the first device support that is loaded for the record type, which will usually be the Soft Channel support that comes with Base.

The OUT link field contains a database or channel access link or provides hardware address information that the device support uses to determine where the output data should be sent to.

Operator Display Parameters

These parameters are used to present meaningful data to the operator. They do not affect the functioning of the record.

  • DESC is a string that is usually used to briefly describe the record.

  • EGU is a string of up to 16 characters naming the engineering units that the VAL field represents.

  • The HOPR and LOPR fields set the upper and lower display limits for the VAL, HIHI, HIGH, LOW, and LOLO fields.

Field

Summary

Type

DCT

Default

Read

Write

CA PP

DESC

Descriptor

STRING [41]

Yes

Yes

Yes

No

EGU

Units name

STRING [16]

Yes

Yes

Yes

No

HOPR

High Operating Range

INT64

Yes

Yes

Yes

No

LOPR

Low Operating Range

INT64

Yes

Yes

Yes

No

Alarm Limits

The user configures limit alarms by putting numerical values into the HIHI, HIGH, LOW and LOLO fields, and by setting the associated alarm severities in the corresponding HHSV, HSV, LSV and LLSV menu fields.

The HYST field controls hysteresis to prevent alarm chattering from an input signal that is close to one of the limits and suffers from significant readout noise.

The LALM field is used by the record at run-time to implement the alarm limit hysteresis functionality.

Field

Summary

Type

DCT

Default

Read

Write

CA PP

HIHI

Hihi Alarm Limit

INT64

Yes

Yes

Yes

Yes

HIGH

High Alarm Limit

INT64

Yes

Yes

Yes

Yes

LOW

Low Alarm Limit

INT64

Yes

Yes

Yes

Yes

LOLO

Lolo Alarm Limit

INT64

Yes

Yes

Yes

Yes

HHSV

Hihi Severity

MENU menuAlarmSevr

Yes

Yes

Yes

Yes

HSV

High Severity

MENU menuAlarmSevr

Yes

Yes

Yes

Yes

LSV

Low Severity

MENU menuAlarmSevr

Yes

Yes

Yes

Yes

LLSV

Lolo Severity

MENU menuAlarmSevr

Yes

Yes

Yes

Yes

HYST

Alarm Deadband

INT64

Yes

Yes

Yes

No

LALM

Last Value Alarmed

INT64

No

Yes

No

No

Monitor Parameters

These parameters are used to determine when to send monitors placed on the VAL field. The monitors are sent when the current value exceeds the last transmitted value by the appropriate deadband. If these fields are set to zero, a monitor will be triggered every time the value changes; if set to -1, a monitor will be sent every time the record is processed.

The ADEL field sets the deadband for archive monitors (DBE_LOG events), while the MDEL field controls value monitors (DBE_VALUE events).

The remaining fields are used by the record at run-time to implement the record monitoring deadband functionality.

Field

Summary

Type

DCT

Default

Read

Write

CA PP

ADEL

Archive Deadband

INT64

Yes

Yes

Yes

No

MDEL

Monitor Deadband

INT64

Yes

Yes

Yes

No

ALST

Last Value Archived

INT64

No

Yes

No

No

MLST

Last Val Monitored

INT64

No

Yes

No

No

Simulation Mode Parameters

The following fields are used to operate the record in simulation mode.

If SIMM (fetched through SIML) is YES, the record is put in SIMS severity and the value is written through SIOL. SSCN sets a different SCAN mechanism to use in simulation mode. SDLY sets a delay (in sec) that is used for asynchronous simulation processing.

See Output Simulation Fields for more information on simulation mode and its fields.

Field

Summary

Type

DCT

Default

Read

Write

CA PP

SIML

Simulation Mode Link

INLINK

Yes

Yes

Yes

No

SIMM

Simulation Mode

MENU menuYesNo

No

Yes

Yes

No

SIOL

Simulation Output Link

OUTLINK

Yes

Yes

Yes

No

SIMS

Simulation Mode Severity

MENU menuAlarmSevr

Yes

Yes

Yes

No

SDLY

Sim. Mode Async Delay

DOUBLE

Yes

-1.0

Yes

Yes

No

SSCN

Sim. Mode Scan

MENU menuScan

Yes

65535

Yes

Yes

No

Invalid Alarm Output Action

Whenever an output record is put into INVALID alarm severity, IVOA specifies the action to take.

  • Continue normally (default)

    Write the value. Same as if severity is lower than INVALID.

  • Don't drive outputs

    Do not write value.

  • Set output to IVOV

    Set VAL to IVOV, then write the value.

Field

Summary

Type

DCT

Default

Read

Write

CA PP

IVOA

INVALID output action

MENU menuIvoa

Yes

Yes

Yes

No

IVOV

INVALID output value

INT64

Yes

Yes

Yes

No

Record Support

Record Support Routines

The following are the record support routines that would be of interest to an application developer. Other routines are the get_units, get_graphic_double, get_alarm_double and get_control_double routines, which are used to collect properties from the record for the complex DBR data structures.

init_record

This routine first initializes the simulation mode mechanism by setting SIMM if SIML is a constant.

It then checks if the device support and the device support’s write_int64out routine are defined. If either one does not exist, an error message is issued and processing is terminated.

If DOL is a constant, then VAL is initialized with its value and UDF is set to FALSE.

If device support includes init_record, it is called.

Finally, the deadband mechanisms for monitors and level alarms are initialized.

process

See next section.

Record Processing

Routine process implements the following algorithm:

  1. Check to see that the appropriate device support module and its write_int64out routine are defined. If either one does not exist, an error message is issued and processing is terminated with the PACT field set to TRUE, effectively blocking the record to avoid error storms.

  2. Check PACT. If PACT is FALSE, do the following:

    • Determine value, honoring closed loop mode: if DOL is not a CONSTANT and OMSL is CLOSED_LOOP then get value from DOL setting UDF to FALSE in case of success, else use the VAL field.

    • Call convert: if drive limits are defined then force value to be within those limits.

  3. Check UDF and level alarms: This routine checks to see if the record is undefined (UDF is TRUE) or if the new VAL causes the alarm status and severity to change. In the latter case, NSEV, NSTA and LALM are set. It also honors the alarm hysteresis factor (HYST): the value must change by at least HYST between level alarm status and severity changes.

  4. Check severity and write the new value. See Invalid Output Action Fields for details on how invalid alarms affect output records.

  5. If PACT has been changed to TRUE, the device support signals asynchronous processing: its write_int64out output routine has started, but not completed writing the new value. In this case, the processing routine merely returns, leaving PACT TRUE.

  6. Check to see if monitors should be invoked:

    • Alarm monitors are posted if the alarm status or severity have changed.

    • Archive and value change monitors are posted if ADEL and MDEL conditions (see “Monitor Parameters”) are met.

    • NSEV and NSTA are reset to 0.

  7. Scan (process) forward link if necessary, set PACT to FALSE, and return.

Device Support

Device Support Interface

The record requires device support to provide an entry table (dset) which defines the following members:

typedef struct {
    long number;
    long (*report)(int level);
    long (*init)(int after);
    long (*init_record)(int64outRecord *prec);
    long (*get_ioint_info)(int cmd, int64outRecord *prec, IOSCANPVT *piosl);
    long (*write_int64out)(int64outRecord *prec);
} int64outdset;

The module must set number to at least 5, and provide a pointer to its write_int64out() routine; the other function pointers may be NULL if their associated functionality is not required for this support layer. Most device supports also provide an init_record() routine to configure the record instance and connect it to the hardware or driver support layer.

The individual routines are described below.

Device Support Routines

long report(int level)

This optional routine is called by the IOC command dbior and is passed the report level that was requested by the user. It should print a report on the state of the device support to stdout. The level parameter may be used to output increasingly more detailed information at higher levels, or to select different types of information with different levels. Level zero should print no more than a small summary.

long init(int after)

This optional routine is called twice at IOC initialization time. The first call happens before any of the init_record() calls are made, with the integer parameter after set to 0. The second call happens after all of the init_record() calls have been made, with after set to 1.

long init_record(int64outRecord *prec)

This optional routine is called by the record initialization code for each int64out record instance that has its DTYP field set to use this device support. It is normally used to check that the OUT address is the expected type and that it points to a valid device, to allocate any record-specific buffer space and other memory, and to connect any communication channels needed for the write_int64out() routine to work properly.

long get_ioint_info(int cmd, int64outRecord *prec, IOSCANPVT *piosl)

This optional routine is called whenever the record’s SCAN field is being changed to or from the value I/O Intr to find out which I/O Interrupt Scan list the record should be added to or deleted from. If this routine is not provided, it will not be possible to set the SCAN field to the value I/O Intr at all.

The cmd parameter is zero when the record is being added to the scan list, and one when it is being removed from the list. The routine must determine which interrupt source the record should be connected to, which it indicates by the scan list that it points the location at *piosl to before returning. It can prevent the SCAN field from being changed at all by returning a non-zero value to its caller.

In most cases the device support will create the I/O Interrupt Scan lists that it returns for itself, by calling void scanIoInit(IOSCANPVT *piosl) once for each separate interrupt source. That routine allocates memory and inializes the list, then passes back a pointer to the new list in the location at *piosl.

When the device support receives notification that the interrupt has occurred, it announces that to the IOC by calling void scanIoRequest(IOSCANPVT iosl) which will arrange for the appropriate records to be processed in a suitable thread. The scanIoRequest() routine is safe to call from an interrupt service routine on embedded architectures (vxWorks and RTEMS).

long write_int64out(int64outRecord *prec)

This essential routine is called when the record wants to write a new value to the addressed device. It is responsible for performing (or at least initiating) a write operation, using the value from the record’s VAL field.

If the device may take more than a few microseconds to accept the new value, this routine must never block (busy-wait), but use the asynchronous processing mechanism. In that case it signals the asynchronous operation by setting the record’s PACT field to TRUE before it returns, having arranged for the record’s process() routine to be called later once the write operation is over. When that happens, the write_int64out() routine will be called again with PACT still set to TRUE; it should then set it to FALSE to indicate the write has completed, and return.

A return value of zero indicates success, any other value indicates that an error occurred.

Extended Device Support

Device Support For Soft Records

Two soft device support modules, Soft Channel and Soft Callback Channel, are provided for output records not related to actual hardware devices. The OUT link type must be either a CONSTANT, DB_LINK, or CA_LINK.

Soft Channel

This module writes the current value using the record’s VAL field.

write_int64out calls dbPutLink to write the current value.

Soft Callback Channel

This module is like the previous except that it writes the current value using asynchronous processing that will not complete until an asynchronous processing of the target record has completed.